M150E - KING PIGEON - 2xRJ45+1xRS485+8DIN+4AIN+4DO Remote IO Module (MQTT, Modbus)
Details
Details
สนใจสามารถสั่งซื้อได้ผ่านช่องทางLazada
The M150 Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.The M150 Ethernet Remote I/O module provides 8 optical-isolated digital inputs, supports max. 700Khz high speed pulse counter, 4 isolated 12bits analog inputs, supports 0~5V,0~10V,4~20mA,0~20mA analog signal, 4 digital outputs, supports 10Hz~300Khz high speed pulse output or relay outputs. All of the I/O with high sampling frequency and special filtering strategy to ensure it’s reliable.
The M150 Ethernet Remote I/O module can work at 12~36VDC with anti-reverse protection design. Also, it provides 1channel 12~36VDC power output for external device to save wiring cost.
Features
1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;2. Power supply 12~36VDC with over voltage and phase-reversal protection;
3. Management and configuration via LAN connection configuration software for easy operation and maintenance;
4. Support Web real-time monitoring and Web debugging;
5. DO1 support PWM output;
6. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP protocol;
7. 8 optical isolated digital input, supports max. 700Khz high speed pulse counter;
8. 4 digital output or relay output, supports 10Hz~300KHz high speed pulse output;
9. 4 isolated analog input, 12-bit resolution, supports 0~20mA,4~20mA,0-5VDC, 0-10VDC;
10. High sampling frequency and special filtering strategy to ensure reliability;
11. 1 RS485 Serial port, supports Modbus RTU Master or Slave, can extend I/O modules;
12. Supports register mapping function and extend I/O inquiry strategy;
13. Provides 1 channel 12~36VDC power source output for external device, saving wiring cost;
14. LED instructions work status, with reset button to reset, easy on-site installation and commissioning;
15. Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;
16. Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.
Specifications
Ethernet Remote I/O Module Specifications | |
• Digital Input | |
Sensor Type | Wet Contact (NPN or PNP), Dry Contact |
I/O Mode | DI or Event Counter |
Dry Contact | • On: short to GND=1 |
Wet Contact (DI to COM) | • On: 10 to 30 VDC=1 |
Counter Frequency | Max. 700kHz(Only the 1st Channel can be used as high speed pulse counter) |
Digital sampling frequency | 500Hz |
Digital filtering strategy | Continues 3 times |
Isolation | Optical Isolated,3k VDC or 2k Vrms |
• Digital Output | |
Type | Sink |
I/O Mode | DO or Pulse Output |
Pulse Output Frequency | 10Hz~300KHz(Only the 1st Channel can be used as high speed pulse outputs) |
Over-Voltage Protection | 50 VDC |
Over-Temperature Shutdown | 175°C (typical), 150°C (min.) |
Load Current | Max. 500 mA per channel |
Digital sampling frequency | 500Hz |
Isolation | If DO is Sink type, then no isolation. If it is Relay, then is electrical isolation. |
• Analog Input | |
Type | Differential input |
Resolution | 12 bits |
I/O Mode | Voltage / Current (jumper selectable) |
Input Range | 0 to 10 VDC, 0 to 20 mA, 4 to 20 mA, 4 to 20 mA |
Accuracy | ±0.1% FSR @ 25°C |
Sampling frequency | 20Hz |
Built-in Resistor for Current Input | 162 ohms |
Isolation | Electrical isolation |
• Working Power Requirements | |
Input Voltage | 12~36VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W; |
Input Current | 139 mA @ 24 VDC |
• Power Output | |
Output Voltage | 12~36VDC |
Output Current | 139 mA @ 24 VDC |
• LAN | |
Ethernet | 10/100 Mbps, RJ45 ports |
Protection | 15KV ESD Protection |
Protocols | Modbus TCP, TCP/IP,MQTT,TCP Server,TCP Client |
Max. TCP Connection | 5 |
• Serial Port | |
RS485 | MODBUS- RTU Protocol |
Protection | 15KV ESD Protection |
Modbus Slave address | 1~255 |
Baud Rate | 1200,2400,4800,9600,19200,38400,57600,115200,128000Bps; |
Mapping registers | Bit Type: 300 Registers, 16-Bit Type: 300 Registers. |
• Physical Characteristics | |
Wiring | I/O cable max. 14 AWG |
Dimensions | 105 x 88 x 30 mm |
Weight | Under 205 g |
Mounting | DIN rail or wall |
• Environmental Limits | |
Operating Temperature | Standard Models: -10 to 60°C (14 to 140°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
Altitude | Up to 3000 m |
Applications
1. BTS Monitoring;
2. Security Alarm System applications;
3. Supervision and monitoring alarm systems;
4. Automatic monitoring system;
5. Vending Machines security protection;
6. Pumping Stations, Tanks, Oil or Water levels;
7. Buildings and Real Estate;
8. Weather Stations;
9. River Monitoring and Flood Control;
10. Oil and gas pipelines;
11. Corrosion protection
12. Temperatures, water leakage applications;
13. Wellheads, boat, vehicle;
14. Energy saving, street lights control system;
15. Valve controls;
16. Transformer stations;
17. Unmanned machine rooms;
18. Control room application;
19. Automation System, M2M;
20. Access Control System;
21. PLC Gateway, PLC Remote Monitoring.